ADCO=0, COCO=0, AIEN=0, ADCH=00000
Status and Control Register 1
ADCH | Input Channel Select 0 (00000): AD0 1 (00001): AD1 2 (00010): AD2 3 (00011): AD3 4 (00100): AD4 5 (00101): AD5 6 (00110): AD6 7 (00111): AD7 8 (01000): AD8 9 (01001): AD9 10 (01010): AD10 11 (01011): AD11 31 (11111): Module disabled Reset FIFO in FIFO mode. |
ADCO | Continuous Conversion Enable 0 (0): One conversion following a write to the ADCSC1 when software triggered operation is selected, or one conversion following assertion of ADHWT when hardware triggered operation is selected. When the FIFO function is enabled (AFDEP > 0), a set of conversions are triggerd. 1 (1): Continuous conversions initiated following a write to ADCSC1 when software triggered operation is selected. Continuous conversions are initiated by an ADHWT event when hardware triggered operation is selected. When the FIFO function is enabled (AFDEP > 0), a set of conversions are loop triggered. |
AIEN | Interrupt Enable 0 (0): Conversion complete interrupt disabled. 1 (1): Conversion complete interrupt enabled. |
COCO | Conversion Complete Flag 0 (0): Conversion not completed. 1 (1): Conversion completed. |
RESERVED | no description available |